Shaanxi Hanzhong Transformer Co., ltd

10KV Transformer Series

10kv level transformer implementation of national standards gb1094 "power transformer" and gb/t6451 "three-phase oil-immersed power transformer technical parameters and requirements", in the structure of the use of rolled iron core, high-stability coil support, improve the reliability of product operation.


1. Transformer core using imported high-quality cold-rolled silicon steel sheet stacked and become, greatly reducing no-load loss and no-load current, and the core is tied to ensure that the tightness of the core, reduce noise.

 2. High and low voltage winding with oxygen-free copper winding, low voltage winding 500kva and the following double-layer cylindrical structure, 630kva or more than double spiral or four spiral structure, high-voltage winding multi-layer cylindrical structure.

 3. The transformer linkage group adopts dyn11, which reduces the impact of harmonics on the power grid and improves the quality of power supply.

 4. The transformer is fully sealed structure, prolonging service life, free of core lifting, free of maintenance.

 5. The measured noise value is lower than the standard.


10KV Transformer Series Specification


10KV s13 Series Sealed Distribution Transformer

TypeRated Capacity ( kVA)Voltage combinationConnection symbolNO-load Loss (kW)load Loss (kW)NO- load Curent , (%)Short-circuit Impedance (%)
HVTapping Rang of HVLV
S13-M-30/10306
6.3
10
10.5
11

±5%

±2x2.5%

0.4Yyn110.080.62.34
S13-M-50/10500.10.872
S13-M-63/10630.111.041.9
S13 -M- 80/10800.131.251.9
S13 -M-100/101000.151.51.8
S13-M-125/101250.171.81.7
S13-M-160/101600.22.21.6
S13 -M -200/102000.242.61.5
S13 -M -250/102500.293.051.4
S13 -M -315/103150.343.651.4
S13- M- 400/104000.414.31.3
S13 -M -500/105000.485.151.2
S13 -M -630/106300.576.21.14.5
S13 -M -800/108000.77.51
S13 -M-1000/1010000.8310.31
S13 -M-1250/1012500.97120.9
SS13-M-1600/1016001.1714.50.8

TypeRated Capaciy (kVA)WeightOverall DimenslonTrack Spacing
OiLTotalLongWideHigh
S13- M-30/103070330880540860400x 400
S13-M-50/105075415900550930400x400
S13 -M-63/106380465930580970400x 450
S13-M-80/1080855209506101000400x 450
S13- M-100/10100955609806501030400 x 450
S13-M-125/1012510065010007001060550x 550
S13-M-160/1016011578011007301105550x550
S13-M-200/1020013088011407751150550x 550
S13-M-250/1025013599012008101170550x 650
S13-M- 315/10315165116012508501250550x 650
S13-M-400/10400195145013008801320660 x 660
S13-M-50010500230168014209001430660x 660
S13-M-630/10630305210016009301460820x 820
S13- M- 800108003452580171010201550820x 820
S13 -M- 1000/1010004002850178010701700820x 820
S13-M-1250/1012505203750185010701780820x 820
S13-M-1600/1016005704050201012301700820 x 820


10KV SH15 Series Sealed amorphous alloy core distribution Transformer

TypeRated Capacity ( kVA)Voltage combinationConnection symbolNO-load Loss (kW)load Loss (kW)NO- load Curent , (%)Short-circuif Impedence (%)
HVTapping Rang of HVLV
S(B)H15-M-30/10
306
6.3
10
10.5
11
±5%
±2x2.5%
0.4Dyn110.0330.5651.74
S(B)H15-M-50/10
500.0430.8201.3
S(B)H15-M-63/10
630.0500.9801.2
S(B)H15-M-80/10
800.0601.1801.1
S(B)H15-M-100/10
1000.0751.4201.0
S(B)H15-M-125/10
1250.0851.7000.9
S(B)H15-M-160/10
1600.102.0800.7
S(B)H15-M-200/10
2000.122.4550.7
S(B)H15-M-250/10
2500.142.8800.7
S(B)H15-M-315/10
3150.173.4450.5
S(B)H15-M-400/10
4000.204.0700.5
S(B)H15-M-500/10
5000.244.8700.5
S(B)H15-M-630/106300.325.5800.34.5
S(B)H15-M-800/10
8000.386.7500.3
S(B)H15-M-1000/10
10000.459.2700.3
S(B)H15-M-1250/10
12500.5310.800.2
S(B)H15-M-1600/10
16000.6313.050.2
S(B)H15-M-2000/10
20000.7515.660.25
S(B)H15-M-2500/10
25000.9018.180.2

TypeRated Capaciy (kVA)WeightOverall DimenslonTrack Spacing
LongWideHigh
S(B)H15-M-30/10
304401000780810400×400
S(B)H15-M-50/10
505551030850850400×400
S(B)H15-M-63/10
636401000900845400×450
S(B)H15-M-80/10
806751060900900400×450
S(B)H15-M-100/10
1007701110910920400×450
S(B)H15-M-125/10
1258801170910950550×550
S(B)H15-M-160/10
1609901220910985550×550
S(B)H15-M-200/10
200115012909201025550×550
S(B)H15-M-250/10
250131013609201060550×650
S(B)H15-M-315/10
315151513808601165550×650
S(B)H15-M-400/10
400187015109001240660×660
S(B)H15-M-500/10
500218516409001295660×660
S(B)H15-M-630/106302720174011201300820×820
S(B)H15-M-800/10
8003200207012301345820×820
S(B)H15-M-1000/10
10003640226013501385820×820
S(B)H15-M-1250/10
12504215236013501445820×820
S(B)H15-M-1600/10
160050002530139015251070×1070
S(B)H15-M-2000/10
200059902750145016501070×1071
S(B)H15-M-2500/10
250070952900151017801070×1072


10Kv So Series Sealed Distribution Transformer

TypeRated Capacity ( kVA)Voltage combinationConnection symbolNO-load Loss (kW)load Loss (kW)NO- load Curent , (%)Short-circuif Impedence (%)
HVTapping Rang of HVLV
S9-M-30/10306
6.3
10
10.5
11
±5%
±2x2.5%
0.4Yyn00.130.62.34
S9-M-50/10500.170.872
S9-M-63/10630.21.041.9
S9-M-80/10800.251.251.8
S9-M-100/101000.291.51.6
S9-M-125/101250.341.81.5
S9-M-160/101600.42.61.4
S9-M-200/102000.482.61.3
S9-M-250/102500.563.051.2
S9-M-315/103150.673.651.1
S9-M-400/104000.84.31
S9-M-500/105000.965.151
S9-M-630/106301.26.20.94.5
S9-M-800/108001.47.50.8
S9-M-1000/1010001.710.30.7
S9-M-1250/1012501.95120.6
S9-M-1600/1016002.414.50.6


TypeRated Capaciy (kVA)WeightOverall DimenslonTrack Spacing
OilTotalLongWideHigh
S9-M-30/103080320830535930400x400
S9-M-50/10509140010556051000400x400
S9-M-63/106310545510556051030400×450
S9-M-80/108011552511006401100400x450
S9-M-100/1010012557511506751100400x450
S9-M-125/1012515769012307351120550x550
S9-M-160/1016016078512307351160550x550
S9-M-200/1020017591013007401185550x550
S9-M-250/10250215111014507451340550x650
S9-M-315/10315225120014907551340550x650
S9-M-400/10400260149014909551360660x660
S9-M-500/10500305167015909601350660x660
S9-M-630/106303752030173510851385820x820
S9-M-800/108005002480173510851470820×820
S9-M-1000/1010005002730182511701495820X820
S9-M-1250/1012506203400182511701760820x820
S9-M-1600/1016007003920201512251760820x820


10KV S11 Series Sealed Distribution Transformer

TypeRated Capacity ( kVA)Voltage combinationConnection symbolNO-load Loss (kW)load Loss (kW)NO- load Curent , (%)Short-circuif Impedence (%)
HVTapping Rang of HVLV
S11-M-30/10306
6.3
10
10.5
11
±5%
±2x2.5%
0.4Yyn00.10.62.34
S11-M-50/10500.130.872
S11-M-63/10630.151.041.9
S11-M-80/10800.181.251.8
S11-M-100/101000.21.51.6
S11-M-125/101250.241.81.5
S11-M-160/101600.282.21.4
S11-M-200/102000.342.61.3
S11-M-250/102500.43.051.2
S11-M-315/103150.483.651.1
S11-M-400/104000.574.31
S11-M-500/105000.685.151
S11-M-630/106300.816.20.94.5
S11-M-800/108000.987.50.8
S11-M-1000/1010001.1510.30.7
S11-M-1250/1012501.36120.6
S11-M-1600/1016001.6414.50.6


TypeRated Capaciy (kVA)WeightOverall DimenslonTrack Spacing
OilTotalLongWideHigh
S11-M-30/1030753151120475985400x400
S11-M-50/1050904109455501005400x400
S11-M-63/10631004609655551040400x450
S11-M-80/1080105505975630995400x450
S11-M-100/1010011055511056351050400x450
S11-M-125/1012512565011607001075550x550
S11-M-160/1016014074512257151135550x550
S11-M-200/1020015085012757751150550x550
S11-M-250/10250185102013357951220550x650
S11-M-315/10315210120014258601335550x650
S11-M-400/10400235141514659701425660x660
S11-M-500/105003001665153510051455660x660
S11-M-630/106303702155184510251640820x820
S11-M-800/108004602565187010151700820x820
S11-M-1000/1010005052825188011051745820x820
S11-M-1250/1012506003575195511201995820x820
S11-M-1600/1016007204070221512302010820x820